EPANET++ is a free web application for modeling water distribution networks, an extension of EPANET.

Scenario comparison

Solves each scenario that is checked in the Scenario manager, all of them unless checks have been cleared, from a copy of the drawing, and tabulates for each the number of overrides, the demand multiplier, the total run time, the hydraulic time step, the lowest pressure, and the highest velocity. Choose Water, Reports, Scenario comparison to open it. The comparison starts when it opens and starts again after each edit while it remains open.

It does not change the project, and the scenario that is open is left as it was.

What the table holds
ScenarioThe name of the scenario. The open scenario is marked (currently open).
No. of overridesThe overrides of the scenario itself, counted as in the Scenarios list. A calculation option such as the demand multiplier counts as one, and an override equal to the inherited value counts.
Demand multiplier, Total run time, Hydraulic time stepThe values the scenario was solved under, its own or those of the project. A steady-state scenario shows a dash for the time step.
Lowest pressureThe lowest pressure at a junction, with its ID and the time it occurs. Reservoirs and tanks are left out because each has a fixed head.
Highest velocityThe highest velocity in a pipe or valve, with its ID and the time it occurs. Pumps are left out.
Steady-state and extended-period scenarios

A scenario with a Total run time greater than 0 is run over the whole period through the EPANET engine. Its lowest pressure and highest velocity are the extremes over every time step, each shown with its time. A scenario with a Total run time of 0 is solved at one instant. The total run time is one of the options a scenario can override, so one table can hold both kinds.

Results by asset

Below the table, Results by asset lists one row per asset of the type chosen in Asset type, with one column for each checked result in each scenario, for example the pressure at every junction in Base, Max day, and Peak hour. A scenario with a total run time is read at the time step on screen, or at its last time step if its run ends sooner, and each heading shows the time read. A scenario that cannot be solved keeps blank columns and a note that says why, and a scenario that did not converge is marked (not converged) in its headings. Copy puts the table on the clipboard as tab-separated text, ready to paste into a spreadsheet. Download CSV saves the same table as a file. Both carry the units in the headings and the numbers in full, without the rounding shown in the box. The sign of a flow is the solver's internal direction sign. It has no use outside the solver except to show in this table whether a flow changed direction between scenarios.

Points to note
  • A scenario that cannot be solved shows the reason in place of its two results, for example that a junction has no path to a source after a pipe is made inactive. The other scenarios are still solved. A scenario that did not converge shows its last results and a message.
  • The block above the table, The same in every scenario, states the friction method, units, accuracy, and maximum trials. A setting that differs between scenarios is left out of the block.
  • There is no pass or fail threshold. Read the numbers against the design criteria of the system being modeled.
  • The example given in the Scenario manager entry compares three scenarios on Net1.